SUPERLITE

HEAT PROTECTION, CLEAR VISION AND COMFORT WITH SUPERLITE

SuperLite I-XL tm is a US manufactured 60 minute fire and safety rated glazing material. It is designed for use in fire doors, sidelites, and windows, where fire protection is required from only one side.

SuperLite I-XL has a proprietary coating which provides radiant heat and fire protection from one direction when the coated surface is oriented to the fire.

APPLICATIONS

This unique product offers a solution to special fire rated conditions: property line demands, retrofit and replacement work, historical buildings, schools & universities, manufacturing facilities and commercial buildings. The SuperLite I-XL product also lends itself to a new market, residential construction and in wildland areas.

SuperLite I-XL carries a 60 minute listing from Warnock Hersey for use in doors, sidelites, and borrowed Iites with special limitations. SuperLite I-XL does not meet the hose stream requirements specified by model building codes, and it is a directional product providing protection from one side only.

Heat from fire is transferred in the form of electromagnetic waves. Invisible, extremely intense, and travelling with the velocity of light, they are able to pass through air without being significantly impaired. Normal monolithic glazing materials will permit a maximum of 50% of this radiant energy to pass.

Application

60 minutes Stops Total Area Width Height Thickness
Door (steel) 5/8" 3.341 sq.in. 35-1/8" 95-1/8" 1/4"
Sidelite (steel) 5/8" 3.341 sq.in. 35-1/8" 95-1/8" 1/4"
Borrowed Lite (steel) 5/8" 3.341 sq.in. 35-1/8" 95-1/8" 1/4"
45 minutes          
Borrowed Lite (steel) 5/8" 3.522 sq.in. 48" 96" 1/4"

BENEFITS

COMPARISON OF FIRE RATED GLAZING PRODUCTS

Recent and conclusive testing by the US Coast Guard and Warnock Hersey Laboratories shows the differences in radiant heat flux amongst fire rated glazing products. Radiant heat testing was conducted on a variety of fire rated glazing products. The results show that considerable heat is transferred through both wired glass and ceramic glazing products.

Another critical point is that there is almost a 100% increase in radiant heat flux through the glazing in the last 15 minutes of a 60 minute fire test. Using a 60 minute fire rated glazing product which doesn’t offer radiant heat protection significantly increases the potential for loss of human life and destruction of property.

SUPERLITE II-XL TAKES THE HEAT

SuperLite I-XL offers considerable protection from the hazards of radiant heat. Supertite I-XL transmits only 1 kilowatt of radiant heat flux at 60 minutes into a fire test when measured 2 meters from the surface of the glazing. SuperLite I-XL is an excellent option in fire rated applications that require clear vision as well as a higher degree of fire resistant protection.

APPLICABLE FIRE AND SAFETY TEST STANDARDS

SuperLite I-XL was exposed to time-temperature curve and fire exposure conditions specified in NFPA 252, Standard Methods of Fire Tests of Door Assemblies.

Surface temperature of the glazing and radiant heat flux were taken at 15 minute intervals.

The cotton pad test in which a cotton pad is placed on the surface of the glazing, was conducted at 15, 30 and 45 minutes. SuperLite I-XL is safety rated conforming to both CPSC 16 CFR part 1201, category II 400ft lbs federal standards and ANSI 797.1 required by Model Building Codes safety standards for use in glazed doors, sidelites, and other hazardous locations.

TECHNICAL DATA
THICKNESS 6 mm
LIGHT TRANSMITTANCE 81%
CUT SIZE TOLERANCE ±2 mm

The Hazards of Radiant Heat

SuperLite™ I-XL at 60 Minutes* 1.8 Kilowatts / Sq. Meter (10 Sq. Ft.)
SuperLite™ II at 60 Minutes* 0 Kilowatts / Sq. Meter (10 Sq. Ft.)
Human Plan 5 Kilowatts / Sq. Meter (10 Sq. Ft.)
Spontaneous Combustion of Wood 16 Kilowatts / Sq. Meter (10 Sq. Ft.)
Wired Glass at 37 Minutes* 39-48 Kilowatts / Sq. Meter (10 Sq. Ft.)

* Measurements taken at 1.5 Meters (5 Ft.) from glazing surface during a fire test.

SuperLite I-XL Fire Performance Statistics

Time Duration 15 Min 30 Min 45 Min 60 Min
Furnace Temperature 1399° F 1550° F 1625° F 1700° F
Exterior Surface Temperatures 420° F 642° F 740° F 740° F
Cotton Pad Test No Ignition No Ignition Ignition at 5 sec. No Measurement
Radiant Heat Flux Measured at tow meters 0 0 0 1 kW
SuperLite provides you with more visibility and less heat.

 

SuperLite™ is warranted against defects in materials and factory workmanship for 10 years.

 

SuperLite I-XL is an excellent option in fire rated applications that require clear vision.

 

Each lite of  SuperLite™ carries a permanently etched logo indicating both fire and safety rating.

 


P.O. Box: 6022, Sharjah, United Arab Emirates.
Tel.: 971 6 5385500, Fax: 971 6 5385155
e-mail: mail@gulfglass.com